ZQ200A Series
It is suitable for low power, small fans/pumps, transportation, woodworking, packaging, food machinery and other fields in general industries.
Keywords: electric motor (motor), reducer, frequency converter
Keyword:
Category:
Product Details
|
Project |
Description |
Specifications |
|
Enter Power |
Voltage range |
Single phase: 200~240V (-20%~+10%) Three-phase: 380~480V (-20%~+10%) |
|
Frequency range |
48-62Hz |
|
|
Output Power |
Output voltage |
Three-phase 0~100% input voltage |
|
Output frequency |
V/F: 0-600Hz; vector control; |
|
|
Control terminal I/O |
Input terminal |
4 digital input terminals |
|
1 analog input terminal (0-10V voltage signal) |
||
|
Output terminal |
1 analog output terminal, only supports output voltage variable 0-10V |
|
|
1 relay output terminal (KA/KB is normally open) |
||
|
Power terminal |
1 channel 10V power supply terminal, maximum output current: 10mA; |
|
|
485 communication |
1 set of communication terminals: RS+/RS-, the maximum baud rate is 38400bit/s; |
|
|
Panel/Display |
5-digit 8-segment LED display |
It can display various data information such as frequency, alarm and status; |
|
Indicator light |
Indicators FOR, REV, Hz, A, L/R display the various states of the inverter; |
|
|
Monitoring function |
Run frequency, set frequency, DC bus voltage, output voltage, output current, output power, PID reference value and feedback value, input terminal state, output terminal state, analog input value, analog output value, inverter Temperature, historical 1-3 fault records and cumulative power-on time and working time, etc.; |
|
|
Environment |
Protection class |
IP20 |
|
Ambient temperature |
-10℃~40℃, derating is required above 40℃; solar radiation is less than 700W/m2; |
|
|
Operating Humidity |
<95%, no condensation; |
|
|
Vibration |
<0.6G; |
|
|
Maximum altitude |
Within 1000m Derating is required for more than 1000m, and the derating is 1% for every 100m increase; the air pressure is 70~106kPa; |
|
|
Motor wire length |
Shielded wire: 50 meters; Unshielded cable: 100 meters; |
|
|
Control Function |
Control mode |
V/F, vector control; |
|
Starting torque |
0.5Hz 150% |
|
|
Overload capacity |
150% rated output current (60s), 200% rated output current (1s); |
|
|
Carrier frequency |
2k~16kHz (vector 10kHz); |
|
|
Open loop speed control accuracy |
30~4000rpm: error ±8rpm; |
|
|
Control command source |
Operation panel digital terminal, communication; |